Multi-parameter patient monitor with optional printer - 12.1 "display
The multi-parameter patient monitor with optional printer is designed to ensure precise and reliable monitoring in clinical contexts. With a high resolution 12.1 "LCD-TFT color display, it offers a clear and detailed view of the vital parameters. The compact and resistant structure is ideal for everyday use, while the integrated handle facilitates transport between the different treatment areas.
This device is able to monitor a wide range of vital parameters, including ECG, breathing (RESP), oxygen saturation (SpO2), non-invasive blood pressure (NIBP), heart rate (PR) and temperature (2- Temp). It is perfect for use on adult and newborn patients, thanks to its versatility and precision. Furthermore, the monitor is equipped with the analysis of the Armythmia, detection of the pacemaker and advanced functions of protection from electrosurgical interference, guaranteeing safe and accurate monitoring in complex medical environments.
The memory of the device allows you to record up to 96 hours of data, with the possibility of storing 500 NIBP measurements and 60 alarm events, thus ensuring a complete and detailed documentation of the patient. The USB port allows you to easily transfer data for further analysis or storage.
Technical features
Display
TFT LCD in color: 12.1 "
Resolution: 800 × 600
Tracks displayed: up to 8
Waveforms displayed: up to 11
Oscillation: 6.25, 12.5, 25, 50 mm / s
ECG
Derivations: 5 derivations and 3 selectable derivations
Display sensitivity: Car x 0.125, x 0.25, x 0.5, x 1, x 2, x 4
Scan speed: 6.25, 12.5, 25, 50 mm / s
Cardiac Beat Range (HR):
Adults 15 ~ 300 BPM
Pediatric / neonatal 15 ~ 350 bpm
Resolution: 1 bpm
Precision: ± 1 bpm or 1%
Filter: Diagnosis mode 0.05 - 150 Hz / Monitoring mode 0.5 - 40 Hz / surgical mode 1 - 20 Hz
Diagnosis mode 0.05 ~ 150 Hz
Monitoring mode 0.5 ~ 40 Hz
Surgical mode 1 ~ 20 Hz
Segment monitoring: Measuring range -2.0 mV ~ 2.0 mV; Alarm range -2.0 mV ~ 2.0 mV
RESP
Method: trans-thoracic impedance
Operation: Automatic / Manual
RR measurement range: Adults 0 ~ 150 rpm; Pediatric / Neonatale 0 ~ 150 BPM
Resolution: 1 rpm
Alarm threshold apnea: 10, 15, 20, 25, 30, 35, 40 s
Bandwidth: 0.2 - 2.5 Hz (-3 dB)
Scan speed: 6.25, 12.5, 25, 50 mm / s
Spo2
Measuring and alarm range: 0 ~ 100%
Resolution: 1%
Precision: ± 2% (70 ~ 100%, adults, pediatric); ± 3% (70 ~ 100%, neonatal)
Pulse measurement: 25 ~ 300 bpm
Resolution: 1 bpm
Update frequency: 1 second
Nibp
Method: Oscillometric automatic
Operation: Manual / automatic / continuous
Measurement interval in automatic mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes
Unit of measurement: mmhg / kPa
Type of measurement: Systolic, diastolic, media
Pressure range:
- adults - systolica 40 ~ 270 mmHg; Diastolic 10 ~ 215 mmHg; Average 20 ~ 235 mmHg
- pediatric - systolic 40 ~ 200 mmHg; Diastolic 10 ~ 150 mmHg; Media 20 ~ 165 mmHg
- neonatal - systolica 40 ~ 135 mmHg; Diastolic 10 ~ 100 mmHg; Media 20 ~ 110 mmHg
Resolution: 1 mmHg
Precision: Max of average ± 5 mmHg
Max standard deviation: 8 mmHg
Measuring range Pulsations from NIBP: 40 ~ 240 bpm
Resolution: 1 bpm
Precision: 3 bpm or 3.5%
Temperature (2 channels, 1 supplied probe)
Measuring / alarm range: 0 ~ 50 ° C
Resolution: 0.1 ° C
Precision: ± 0.1 ° C (without probe)
Channel: 2
Printer (Optional)
Print speed: 25, 50 mm / s
Power
Socket: 100 ~ 240 V AC, 50/60 Hz
Rechargeable lithium battery: 14.8 V
Size L: 32 x D: 15 x h: 26.5 cm
Weight 5 kg
Data sheet