Monopolar active electrode with protected tungsten needle, length 55 mm (51 mm insulated). Standard shaft 2.38 mm, compatible with electrosurgery handles. Sterile, single-use, in a single pouch. Available in a pack of 4 pieces or in a box of 24.
Security policy (edit with Customer reassurance module)
Delivery policy (edit with Customer reassurance module)
Return policy (edit with Customer reassurance module)
The FIAB F4051/TU electrode is an active tungsten needle electrode for monopolar electrosurgery, produced in Italy by FIAB S.p.A. The tungsten series is designed for procedures that require very precise cutting and coagulation, such as microdissection.
The needle is protected by an insulating coating for 51 mm of the total 55 mm: the energy is concentrated only at the tip, reducing the risk of lateral tissue burns.
Conducts energy from the monopolar electrosurgical generator to the surgical site for cutting and coagulating tissues. For use by qualified healthcare personnel only.
Do not use on patients with pacemakers or other active implants without first consulting a cardiologist. Do not use if the packaging is open or damaged or if the insulation is visibly damaged. Do not reuse. Consult the instructions for use before use.
| Manufacturer code (REF) | F4051/TU |
| Manufacturer | FIAB S.p.A., Vicchio (FI), Italy |
| Type | Protected monopolar active needle electrode |
| Needle material | Tungsten |
| Total length | 55 mm |
| Insulated length | 51 mm |
| Shape | Straight needle |
| Shank diameter | 2.38 mm (3/32") |
| Maximum applicable voltage | 9 kVpp |
| Sterilization | Ethylene oxide |
| Use | Single-use |
| Latex | Absent |
| Class | IIb, Regulation (EU) 2017/745 (MDR) |
| Notified body | BSI, no. 2797 |
| Packaging | Single sterile pouch; sold in packs of 4 pieces or in original box of 24 |
| Validity | 4 years from production |
| Storage | 0–50 °C, humidity 20–80%, protected from sunlight |
Monopolar active electrode with protected tungsten needle, length 55 mm (51 mm insulated). Standard shaft 2.38 mm, compatible with electrosurgery handles. Sterile, single-use, in a single pouch. Available in a pack of 4 pieces or in a box of 24.